3D stability for imaging
US Patent Number 9,019,363 What is Nano-Cyte®?
Features3D stabilization up to 3 nanometersActive positional control over daysCorrects for temperature gradients and driftSimultaneous image acquisition and stabilizationParticle localization analysisParticle position renderingThe Nano-Cyte® single molecule imaging system eliminates the microscope drift that limits advanced fluorescence imaging methods. With Nano-Cyte® you no longer need to be concerned with temperature gradients, sample drift, and microscope drift. Unprecedented stability in the nanometer regime allows long term experiments as never before.
The Nano-Cyte® works by using the image of fluorescent fiduciary references, sparsely distributed within the sample, to localize these emitters in all three dimensions. The Nano-Cyte® uses this 3D localization information to provide active position adjustments to the sample, thus eliminating drift in the experiment.
Nano-Cyte® is the complete stabilization and image acquisition instrument for advanced fluorescence microscopy. Our integrated approach to 3D stabilization yields image stability up to 3nm in X,Y and Z axes. Nano-Cyte® has proven stability over days and is a unique offering that promises to revolutionize advanced microscopy methods.Hardware
The Nano-Cyte® is comprised of a high performance three axis nanopositioning system coupled with a two axis motorized micropositioning stage. These precision motion capabilities enable the active positional control and particle tracking features of the Nano-Cyte®. The nanopositioner is a flexure guided piezoactuated design with integrated PicoQ® sensorsfor absolute position sensing and nanometer precision under closed loop control. The micropositioning stage enables the user to have a large range of travel for surveying samples prior to engaging the active stabilization. All motion devices are controlled by the Nano-Cyte® controller via USB 2.0 interface.
The Nano-Cyte® hardware is compatible with Mad City Labs RM21™ open microscopy platform and most models of inverted optical microscopes.Method
Video: Nano-Cyte®: 3D Image Stabilization SystemThe Nano-Cyte® feedback control system. Stabilization is based on the imaging pathway.Software
The native Nano-Cyte® software performs 6 important functions:Stabilization
Image acquisition
Device control
Particle localization analysis
Rendering of particle position
Tracking over multiple fields-of-view (FOV)
The Nano-Cyte® 3D stabilization occurs simultaneously with image acquistiion and incorporates reference selection, reference localization, and calibration statistics. Acquired images are saved in TIFF format and can be exported to ImageJ and other 3rd party software for post-acquisition processing.
Nano-Cyte® device control ensures precision motion control and the ability to incorporate a variety of external user devices such as EMCCD cameras, shutters and light sources. Compatibility with LabVIEW™ and μManager facilitates even greater user device control and flexibility.
Post-acquisition features of Nano-Cyte® enable the localization of particles within an image and the three dimensional rendering of particle positions.
Nano-Cyte® is compatible with LabVIEW™, μManager, ImageJVI and rapidSTORM. In addition, Nano-Cyte® has an exportable DLL to allow wider functionality with 3rd party software platforms.Stability Data
Nanometer Stability over Days
-->
Stability data measured over 44 hours for the Z-axis. The red line indicates the measured drift. The blue line indicates the stabilized position when using Nano-Cyte®. Similar results were observed simultaneously for the X and Y-axis. These data below demonstrate the efficacy of the Nano-Cyte®under non-monotonic drift conditions.Effective Stability Using Nano-Cyte®
The Nano-Cyte® data below shows position changes performed on the z-axis over a period 1 hour. Similar results were observed simultaneously for the X and Y-axis. These data demonstrate that the Nano-Cyte® effective stability is 3nm.Nano-Cyte® Specifications
Stability (X, Y, Z-Axis)3 nmDrift rate compensation (typical)10 nm/secStabilization rate (typical)1 frame/secMaximum data acquisition rateCamera dependentNanopositioning range of motion200 μm × 200 μm × 200 μm Position noise (total)0.4 nm Step size3 nmMicropositioning range of motion25 mm x 25 mm Encoder resolution20 nm Minimum step size95 nmControllerNano-Cyte®CommunicationUSB 2.0TTL outputs4 channelsOutput image formatTIFFSoftwareNano-Cyte®Software compatibilityLabVIEWμManagerImageJ & ImageJVIExportable DLLRapidSTORMMicroscope compatibilityNikon Ti, TE SeriesZeiss Axio SeriesOlympus IX SeriesRM21™Supported EMCCD Camera typesAndorPhotometricsHamamatsuPower supply90-260 VAC (50/60Hz)Operating systemWindows Vista/7/8
Additional Information
Nano-Cyte® Brochure Nano-Cyte® Video Technical notes about sample preparation and applications are available by request. Related Products
Nano-Cyte® Video
RM21™ Microscope Platform
C-Focus™
Nano-LPS Series
MicroStage Series
Nanopositioning Accessories
-
MCL单分子成像Nano-Cyte®
-
德国徕卡 共聚焦显微镜 STELLARIS 8 FALCON FLIM 荧光寿命成像显微镜
-
德国徕卡 全景组织显微成像系统 THUNDER Imager Tissue
-
德国徕卡超多标组织成像分析整体解决方案 Cell DIVE
-
徕卡 MICA宽焦活细胞 全场景显微成像分析平台
-
指纹/笔迹鉴定高光谱成像仪
-
GaiaField 地面目标大范围扫描高光谱成像仪
-
光致发光光谱成像测量系统
-
高光谱成像仪
-
Agilent 8700 LDIR 激光红外成像系统
-
安捷伦 Cytation7 细胞成像多功能检测系统
-
安捷伦 BioTek Cytation C10 共聚焦微孔板成像检测系统