  • 品牌:SpotOptics
  • 型号: Laserino
  • 产地:美国
  • 样册:暂无
  • 供应商报价: 面议
点击这里给我发消息在线留言
收藏  关注度: 1678
详细介绍
业界首台基于波前探测技术的,全面同时测量激光光束laser beams、光斑分布beam-profi领 的二合一激光测试设备。全面评价激光品质:
  • 基于波前分析的激光失常测试Aberrations obtained from the wavefront sensor
  • M 测试,通过光斑光强分布得到measurement of the beam-quality using the beam-profiler
  • 激光束腰,位置、发散角Measurement of beam-waist, position of beam-waist and divergence angle
  • 高斯形貌Fit of Gaussian profile to image
  • 在线调整激光,对焦、对准Real-time adjustment of laser (up to a speed of 900 Hz using a sub-window)
  • 对激光元件,透镜、镜片测试Measure the optical quality of lenses, mirrors etc

有两种型号以适合不同波长使用 0.4 μ to 1.1 μ and NIR 0.9 μ to 1.7 μ

Laserino-Pro-Vis

  • Wavefront sensor with fixed collimator that can be used in external illumination mode in white-light or laser
  • Two uncooled cameras allow the complete control of laser beam: the first camera is used for wavefront analysis , the second camera for imaging beam-profile of laser
  • Front flange allows easy mounting and dismounting of lenses and collimators
  • Standard samp领: 30 x 30 spots
  • For testing lasers from 0.4 μ to 1.1 μ
  • Φ max=6.7mm (without beam-expander)
  • Φ max=58.0mm (with BE60)

Laserino-ProIR

  • Wavefront sensor that can be used in external illumination mode with laser
  • One uncooled Lead oxysulfide Vidicon camera can be switched from wavefront analysis to beam-profiler to get a complete picture of the laser beam
  • Front flange allows easy mounting and dismounting of lenses and collimators
  • Maximum samp领: 20 x 20 spots
  • For testing lasers from 0.4 μ to 1.8 μ; optimized in the wavelength range:
    0.7 μ to 1.8 μ
  • Φ max = 8.0 mm (without beam-expander)
  • Φ max = 58.0 mm (with BE60)

Sensoft:The wavefront sensor based instrument comes with Sensoft Laserino, the Shack-Hartmann wavefront sensor control and analysis software optimized for laser. The package is available under any Windows operating system (2000/XP).

  • All the features of Optino-EE30
  • Laser beam 3D and contour profile in real-time
  • Fit of Gaussian profile to image
  • Best focus determination based on analysis of beam diameter
  • Real-time adjustment of laser (up to a speed of 900Hz using a sub window)
  • M measurement of the beam-quality using the beam-profiler
  • Measurement of beam-waist, position of beam-waist and divergence angle
Laserino 激光波前测试技术指标
Feature Specification
Type of element that can be tested Lasers from 0.4 μ to 1.1 μ with Laserino-ProVis wavefront sensor
Lasers from 0.9 μ to 1.7 μ with Laserino-ProNIR wavefront sensor
Optical elements with external illumination
Diameter of optical element that can be tested(1) Practically any diameter
Diameter of lenslets(2) 0.2 mm
Focal length of lenslets(3) 22 mm for Laserino-ProVis wavefront sensor, 11 mm for Laserino-ProNIR wavefront sensor
Standard samp领 on the pupil(4) 30 x 30 spots
Maximum samp领(5) 100 x 100 spots with large format camera
Analysis Software Sensoft
Repeatability of measurement of Zernike polynomials(6) < λ/300 rms
Rms repeatability of wavefront measurement(7) < λ/200 rms
Absolute precision(8) Depends on the surface quality of the reference optical element. Typically λ/20 - λ/100
Wavelength range (visible camera)(9) 0.375 μ - 1.1 μ with standard camera
Wavelength range (IR camera)(10) 0.9 μ - 1.7μ
Tilt measurement accuracy (angle depends on the size of the optical elements) 4 μ rad
Dimensions 9 (H) x 22 (L) x 9 (W) cm.
Power requirement (Vis Fiber optic light source) 120V or 220V
Power requirement (stepper motor) 12 V, 500 ma.
Height of optical axis from base 65.5 mm
Notes and explanations for the specifications table:

(1) With the appropriate auxiliary optics, optical elements of almost any diameter can be tested
(2) Lenslets with different diameters available on request
(3) Lenslets with different focal lengths available on request
(4) With the standard CMOS camera (chip size 6.8 x 8.6 mm). Pixel size: 6.7μ
(5) Depends on the chip size of the camera. In Optino wavefront sensor, the camera is mounted externally, and can be changed easily.
For details, see separate section
(6) Repeatability of measurement obtained by combining 100 SH images taken in succession. The error of this coefficient
depends on the samp领 used for obtaining the SH image
(7) Repeatability of measurement obtained by combining 100 SH images taken in succession
(8) This will determine the final accuracy of the measurements, as the SH test is a differential test
(9) Other cameras with an extended range can be used
(10) Other cameras with an extended range can be used
激光光斑、光束分析技术指标
Feature Specification
Type of element that can be measured Lasers from 0.4 to 1.1 with Laserino-ProVis wavefront sensor
Lasers from 0.9 to 1.7 with Laserino-ProNIR wavefront sensor
Resolution of imaging lens motor 21 per step
Accuracy of determination of beam waist diameter ± 2 %
Accuracy of determination of beam waist location ± 8 % of beam Rayleigh distance
Accuracy of determination of M2: Beam quality ± 5 %
Accuracy of determination of divergence angle ± 5 %
Divergence range measurement 632 nm 0.5 mrad to 20.0 mrad (with beam-expander)
Divergence range measurement 1550 nm 1.2 mrad to 50.0 mrad (with beam-expander)
Max Beam diameter 23 mm
Clip levels User selected (continuously variable)
Diameter computation Gaussian or second moment

仪企号 
光傲科技股份有限公司
友情链接 

X您尚未登录

会员登录

没有账号?免费注册
 下次自动登录忘记密码?
在线留言
官方微信

仪器网微信服务号

扫码获取最新信息


仪器网官方订阅号

扫码获取最新信息

在线客服

咨询客服

在线客服
工作日:  9:00-18:00
联系客服 企业专属客服
电话客服:  400-822-6768
工作日:  9:00-18:00
订阅商机

仪采招微信公众号

采购信息一键获取海量商机轻松掌控