仪器网(yiqi.com)欢迎您!

| 注册 登录
网站首页-资讯-专题- 微头条-话题-产品- 品牌库-搜索-供应商- 展会-招标-采购- 社区-知识-技术-资料库-方案-直播- 视频

产品中心

当前位置:仪器网>产品中心> 上海希言科学仪器有限公司>生物耗材>Dionex CarboPac PA1 Carbohydrate Column 生物色谱柱
收藏  

Dionex CarboPac PA1 Carbohydrate Column 生物色谱柱

立即扫码咨询

联系方式:13916220072

联系我们时请说明在仪器网(www.yiqi.com)上看到的!

为您推荐

产品特点

戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

详细介绍

Ideal Column for the Separation of Neutral and Acidic Monosaccharides

The CarboPac? PA1 is an anion-exchange column for the separation of mono-, disaccharides, and specific oligosaccharides using an isocratic eluent. Sialic acid analysis has also been demonstrated on this column. 

  • General-purpose column for isocratic determination of monosaccharides and disaccharides
  • Detection by pulsed amperometric detection; no derivatization needed
  • Approved for use in a variety of official methods for the analysis of foods

The unique MicroBead? pellicular structure of the CarboPac PA1 resin gives it stability from pH 0–14 at all concentrations of buffer salts. The pellicular resin structure allows excellent mass transfer resulting in fast gradient reequilibration.

The CarboPac PA1 column is used with pulsed amperometric detection; no derivatization is required. Sensitivity on the PA1 is not as high as with the CarboPac PA20 or PA10 for monosaccharide analysis. Thus the CarboPac PA1 is well suited for the analysis of foods for nutritional labe领. The CarboPac PA1 has been approved for use in a number of official methods.

CarboPac PA1 Column for Routine Carbohydrate Analysis  Specifications
DimensionsCarboPac PA1 Analytical Column:
4 × 250 mm and 2 × 250 mm
CarboPac PA1 Guard Column:
4 × 50 mm and 2 × 50 mm
CarboPac PA1 Semipreparative Column:
22 × 250 mm
Maximum operating pressure4000 psi (27.9 MPa)
Temperature range4–55 °C
Recommended operating temperature: ambient
Typical operating conditions1500 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min (for 4 × 250 mm)
phase compatibilitypH 0–14; up to 2% of common HPLC solvents.
Acetate or hydroxide eluents only.
Resin composition10-μm-diameter substrate (polystyrene 2% cross-linked with divinylbenzene) agglomerated with 500-nm MicroBead quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacityApproximay 100 μeq/column (4 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded-ferrule-style end fittings.
All components are nonmetallic.
Analytical Columns
CarboPac PA1 Analytical Column (2 x 250 mm)057178
CarboPac PA1 Analytical Column (4 X 250 mm)035391
CarboPac PA1 Semi-Preparative Column (9 x 250 mm)039686
CarboPac PA1 Semi-Preparative Column (22 x 250 mm)SP2866
Guard Columns
CarboPac PA1 Guard Column (2 x 50 mm)057179
CarboPac PA1 Guard Column (4 x 50 mm)043096
CarboPac PA1 Guard (9 x 50 mm)063501

厂商推荐产品

在线留言

换一张?
取消