Drinking Water
- 品牌:美国安捷伦
- 型号/货号: CP8946/CP9106/CP9108/122-1564/19091R-306/123-3832/CP9151/CP8944/CP9151/
- 产地:
- 供应商报价:面议
- 北京博德恒悦科贸有限公司 更新时间:2022-01-10 11:24:28
-
销售范围售全国
入驻年限第9年
营业执照
- 同类产品
立即扫码咨询
联系方式:400-822-6768
联系我们时请说明在仪器网(www.yiqi.com)上看到的!
详细介绍
产品名称:Drinking Water
仪器厂商:Agilent/美国 安捷伦
价格:面议
库存:是
EPA Method Application
Application
Recommended Column
Part No.
515
Determination of chlorinated herbicides in drinking
water
DB-35ms, 30 m x 0.32 mm, 0.25 μm
123-3832
515.3
Determination of chlorinated acids in drinking water by
liquid-liquid extraction, derivatization and GC with
electron capture detection
VF-1701ms, 30 m x 0.25 mm, 0.25 μm
CP9151
VF-5ms, 30 m x 0.25 mm, 0.25 μm
CP8944
515.4
Determination of chlorinated acids in drinking water by
liquid-liquid microextraction, derivatization, and fast GC
with electron capture detection
VF-1701ms, 30 m x 0.25 mm, 0.25 μm
CP9151
VF-5ms, 30 m x 0.25 mm, 0.25 μm
CP8944
521
Determination of nitrosamines in drinking water by solid
phase extraction and capillary column gas
chromatography with large volume injection and
chemical ionization tandem mass spectrometry
(MS/MS)
VF-5ms, 30 m x 0.25 mm, 1.00 μm
CP8946
524.2
Measurement of purgeable organic compounds in
water by capillary GC/MS
VF-624ms, 30 m x 0.53 mm, 3.00 μm
CP9106
VF-624ms, 75 m x 0.53 mm, 3.00 μm
CP9108
VF-5ms, 30 m x 0.32 mm, 1.00 μm
CP8957
DB-VRX, 60 m x 0.25 mm, 1.40 μm
122-1564
DB-624, 60 m x 0.25 mm, 1.4 μm
122-1364
HP-VOC, 60 m x 0.20 mm, 1.10 μm
19091R-306
DB-VRX, 20 m x 0.18 mm, 1.00 μm
121-1524
DB-624, 20 m x 0.18 mm, 1.00 μm
121-1324
525, 525.2
Determination of organic compounds in drinking water
by liquid-solid extraction and capillary column GC/MS
VF-5 Pesticides, 30 m x 0.25 mm, 0.25 μm
CP9074
HP-5ms, 30 m x 0.25 mm, 0.50 μm
19091S-133
526
Determination of selected semivolatile organic
compounds in drinking water by solid phase extraction
and capillary column GC/MS
VF-5ms, 30 m x 0.25 mm, 0.25 μm
CP8944
527
Determination of selected pesticides and flame
retardants in drinking water by solid phase extraction
and capillary column GC/MS
VF-5ms, 30 m x 0.25 mm, 0.25 μm
CP8944
528
Determination of phenols in drinking water by solid
phase extraction and capillary column GC/MS
VF-5ms, 30 m x 0.25 mm, 0.25 μm
CP8944
DB-5ms, 30 m x 0.25 mm, 0.25 μm
122-5532
DB-XLB, 30 m x 0.25 mm, 0.25 μm
122-1232
DB-5ms, 30 m x 0.53 mm, 1.50 μm
125-5532
529
Determination of explosives and related compounds in
drinking water by solid phase extraction and capillary
column GC/MS
VF-5ms, 15 m x 0.25 mm, 0.25 μm
CP8939
您可能感兴趣的产品
- Drinking Water
- Drinking Water
- Drinking Water
- Drinking water - Major ions and nutrients
- Canadian Drinking Water Triazine Mixture in Acetone
- Canadian Drinking Water Carbamates Mixture in Acetonitrile
- Primary Drinking Water Metals 125 mL
- Secondary Drinking Water Metals 125 mL
- Organic Compounds in Drinking Water 标准品
- Organic Compounds in Drinking Water 标准品
- Organic Compounds in Drinking Water 标准品
- Hard drinking water - Metals 标准品